How Can We Help?
Search for answers or browse our knowledge base.
-
Retro C
-
-
- Articles coming soon
-
- Replace the Retro C Computer
- Configure the Touchscreen Computer to Power On Automatically
- Replace the microSD Card in a Display Computer
- Transfer Files to the Retro C
- Replace the USB Drive in the Touchscreen Computer
- Configure a Newer Computer to Power On After an Outage
- Configure an Older Computer to Power On After an Outage
- Touchscreen Pointer Is Flipped or Mirrored
- Replace the Retro C Touchscreen USB Drive
-
-
-
- Recover and Recalibrate a Stuck Angle or Centerline
- Replacing an Angle Encoder
- Angle Movement Overruns the Commanded Position
- Angle (Arch) Movement Overview
- Angle Chains – Proper Chain Tension
- Diagnose Unknown Blade Motor Noises
- Pivot Point Calibration Check
- Troubleshoot Power or Wiring for Angle Motors and VFDs
- Dirty Saw Head Slide: Symptoms and Cleaning
-
- Recover and Recalibrate a Stuck Angle or Centerline
- Calibrate Retro C Centerlines 1–5
- Advanced Centerline Recovery When Calibration Is Far Out
- Centerline (Vertical) Movement Overview
- Replace a Centerline Encoder
- Replacing a Centerline Gearbox
- Check the Centerline Maximum and Minimum Height Settings
- Tighten the Centerline Slides
- Adjust Centerline Chain Tension
-
-
- Third Scrap Drive Wiring and GS23 Programming
- Adjust or Tighten the Scrap Conveyor Belt
- Configure the Scrap or Incline Conveyor to Always Run
- Replacing the Scrap Motor
- Scrap Belt: Support Roller Replacement
- Scrap Belt Sweeper Adjustment and Inspection
- Scrap Belt Tracking and Alignment
- Retro C Scrap System Overview and Daily Checks
-
-
- VFD General Reference and Troubleshooting
- Drive (VFD) Disconnected Warning: Diagnosis and Recovery
- GS1 and GS2 VFD Reference
- GS20 VFD Reference
- GS20 ACM/DCM Common Wiring
- GS20 Standard VFD Wiring Reference
- GS3 VFD Reference
- Program a Replacement CFW Drive
- GS VFD Overvoltage Warning: Diagnosis and Safe Response
- VFD Replacement Options
- Yaskawa V1000 Blade Programming
- Program an AutomationDirect GS23 VFD
- Common VFD Wiring to VC1s
-
- Replace and Commission a VC1
- Replace a VC1: Mechanical and Electrical Procedure
- Add a Delay Diode Jumper to a VC1
- Configure the Software After Replacing a VC1
- Temporary 24 V UPS Bypass: Qualified-Technician Procedure
- VC1 Standard Jumper Removal
- 24 AWG-to-22 AWG VC1/VFD Cable Upgrade Wiring Reference
- VC1 Status Lights and Startup Diagnosis
-
- Encoder Wiring Diagram
- Stationary and Carriage Panel Cable Entry Layout
- Troubleshoot Power or Wiring for Angle Motors and VFDs
- Replace the Wires and Hoses in the Energy Chain
- Temporary 24 V UPS Bypass: Qualified-Technician Procedure
- 24 AWG-to-22 AWG VC1/VFD Cable Upgrade Wiring Reference
- Common VFD Wiring to VC1s
-
-
- Common Retro C Issues and Solutions
- Countdown Timer Warning with All VC1s and VFDs Disconnected
- Scrap Belt or Scrap Incline VFD Disconnected: Troubleshooting
- Recover and Recalibrate a Stuck Angle or Centerline
- Touchscreen Pointer Is Flipped or Mirrored
- Encoder Unplugged Error: Diagnosis and Recovery
- Stationary or Carriage Horizontals Will Not Move
- Error Messages and Warnings: Quick Index
-
-
-
Linear Pickline
-
- Foot Pedal Controls and Troubleshooting
- Unexpected Conveyor Movement Caused by a Foot Pedal Contact
- Front Conveyor Sensor: Location and Diagnosis
- Kindle Fire 8 Configuration
- Linear PickLine – Conveyor Sensor Integration
- Linear PickLine – Installation Requirements
- Linear PickLine – Installing the Brain Box
- SmartConveyor Air Stop: Operation and Troubleshooting
-
-
Plant One Projection
-
SmartConveyor
-
- Cable Pull Emergency-Stop System
- SmartConveyor V40 Encoder: Route, Replacement, and Verification
- Foot Pedal Controls and Troubleshooting
- Unexpected Conveyor Movement Caused by a Foot Pedal Contact
- Front Conveyor Sensor: Location and Diagnosis
- SmartConveyor Dual-Pedal Controls
- SmartConveyor Air Stop: Operation and Troubleshooting
-
-
Sticker Printer
-
NexPlate
< All Topics
Print
Error Messages and Warnings: Quick Index
Updated
Applicability
| Product | Retro C and supported VFDs |
|---|---|
| Subsystem | Error and warning diagnosis |
| Skill level | Operator or maintenance technician; follow the qualification requirements in the linked article |
| Lockout/tagout | Not required to use this index; follow the safety and energy-control instructions in the selected diagnostic article |
Find the wording shown on the Retro C Check screen, popup, or VFD display below, then open the matching diagnostic article. Similar messages can have different causes, so use the screen location and number of affected devices to choose the correct path.
Error and Warning Index
| Screen text or condition | When this entry applies | Start here |
|---|---|---|
| “Crossup Detected” | A popup pauses material feeding because the two material-feed sensors do not agree. | Crossup Detected Error: Cleaning and Aligning the Material Feed Sensors |
| “Disconnected” | The Check screen shows one VFD or drive as disconnected. | Drive (VFD) Disconnected Warning: Diagnosis and Recovery |
| “Disconnected” — Scrap Belt or Scrap Incline | The affected devices are specifically the scrap belt or scrap incline VFDs. | Scrap Belt or Scrap Incline VFD Disconnected: Troubleshooting |
| “Countdown Timer” | The warning remains and all stationary and carriage VC1s and VFDs show disconnected. | Countdown Timer Warning with All VC1s and VFDs Disconnected |
| “Encoder Unplugged” | An affected movement reports an encoder connection or feedback problem. | Encoder Unplugged Error: Diagnosis and Recovery |
| “Encoder Error” | A yellow status indicates that the encoder problem recovered. The warning should clear after the next machine movement. | Encoder Unplugged Error: Diagnosis and Recovery |
| “Overvoltage” | A GS VFD reports an overvoltage warning. Record the complete drive code if one is shown. | GS VFD Overvoltage Warning: Diagnosis and Safe Response |
Useful Search Variants
Related searches include: crossup, cross up, VFD disconnected, drive offline, lost communication, encoder unplugged, encoder error, encoder not counting, over voltage, VFD fault, all VC1s disconnected, and all drives disconnected.
If Your Message Is Not Listed
- Record or photograph the exact message.
- Record the affected movement, component, or drive number.
- Note the indicator-light state and whether one or multiple devices are affected.
- Record when the message appeared and the steps already attempted.
Contact Enventek Technical Support at 269-815-4150 if the fault remains, the machine does not respond as expected, or the displayed wording does not match an entry above.