Before You Begin

Safety: Stop the machine, follow the site lockout/tagout procedure, verify that hazardous energy is controlled, and release or secure stored mechanical and pneumatic energy before opening a panel, removing a guard, or adjusting components. Electrical work must be performed by a qualified technician.

The Linear Pickline has the ability to work with other types of saws from nearly any manufacturer through the implementation of an integrated sensor array. The Linear Pickline’s sensor array will detect if a board is removed from one or more of the sensors and start indexing wood until the area is full or it times-out. This integration allows the Pickline to work with various 3rd party Linear saws, as it provides a way for an existing conveyor to pull lumber away while the Linear Pickline will just keep it full.

Confirm the Result

Reinstall all guards and restore energy through the approved startup procedure. Run a controlled no-load test, watching for binding, tracking changes, unusual noise, vibration, leaks, or unexpected movement before returning the machine to production.

If the issue remains, record the exact on-screen message, affected component, indicator-light state, and the last change made. Provide those details to Enventek Technical Support; do not repeatedly recalibrate or replace parts without identifying the cause.