Configure the Scrap or Incline Conveyor to Always Run

Before You Begin

Safety: Stop the machine, follow the site lockout/tagout procedure, verify that hazardous energy is controlled, and release or secure stored mechanical and pneumatic energy before opening a panel, removing a guard, or adjusting components. Electrical work must be performed by a qualified technician.

Step 1: Go to the VFD that controls the Scrap Conveyor (DR30) or the Scrap Incline (DR31), both are located in the scrap enclosure and take the front plastic cover off. Use a single strand of ethernet wire (color doesn’t matter) to connect the “DCM” terminal to the “FWD” terminal.

Step 2: On the VFD change these settings using the keypad

  • Press Enter:
  • Select: 00
  • Press Enter
  • Select 00.20
  • Press Enter:
  • Select: 0
  • Press Enter
  • Press Menu
  • Select 00.21
  • Press Enter
  • Select: 1
  • Press Enter
  • Press Menu
  • Select 00.22
  • Press Enter
  • Select: 1
  • Press Enter

Step 3: Using the Up and Down arrow keys on the keypad select anything from 0 to 60. 0=no movement , 60= Full speed

We would suggest adding a switch between DCM and FWD in order to turn the conveyor on and off as need. The switch can be drilled into the scrap enclosure.

Confirm the Result

Reinstall all guards and restore energy through the approved startup procedure. Run a controlled no-load test, watching for binding, tracking changes, unusual noise, vibration, leaks, or unexpected movement before returning the machine to production.

If the issue remains, record the exact on-screen message, affected component, indicator-light state, and the last change made. Provide those details to Enventek Technical Support; do not repeatedly recalibrate or replace parts without identifying the cause.